What a fire alarm takeoff is
Before a fire alarm bid can be priced, somebody has to count what is on the drawings: every smoke detector, pull station, horn/strobe, speaker, module and panel, sheet by sheet, and write the quantities down in a form the estimate can use. That count is the takeoff. Wire, conduit and labour are priced from it, so a device missed here is missed all the way through the bid.
A good takeoff is not one number. It separates:
- Device type. Smoke detector, heat detector, duct smoke detector, pull station, horn/strobe, speaker/strobe, strobe, speaker, monitor module, control module, relay, and the rest of the set's legend.
- The attributes that change the part number. Candela rating (15, 30, 75, 110 cd), wall or ceiling mounting, weatherproof variants, and duct smokes on their own line. Two strobes with different candela are two different parts. The attributes guide goes through each one.
- Where it is. Counts by sheet and by floor, so the material can be staged and the labour spread, and so an addendum that changes one sheet changes one line.
- What is adjacent but not yours to count the same way. Tamper and flow switches, dampers, panels and annunciators are on the fire alarm drawings but are usually priced differently or by someone else. They belong in a separate section, not in the device total.
How estimators count a set by hand
- Read the legend first. Every set draws its symbols a little differently. The legend sheet (often FA-001 or FA0.0) tells you what a hexagon with an S means on this job, which suffix means ceiling, and how weatherproof is marked.
- Mark as you count. On paper that is a highlighter, one colour per type. In a PDF tool it is a count markup. Either way, a device that is not marked is a device you cannot prove you counted.
- One type at a time, one sheet at a time. Sweep the sheet for smokes, then for pulls, then for notification appliances, reading the candela tag beside each strobe as you go.
- Watch the typical floors. A sheet titled "4th and 5th floors (typical)" is one drawing standing for two floors. Count it once as drawn, then decide how to extend it, and write down what you did.
- Tally into the estimate. Totals by type and attribute, by sheet, into the spreadsheet or the estimating package.
- Re-count on every addendum. Revised sheets mean the whole sheet is counted again, because nothing tells you which devices moved.
A dense plan sheet, say a hospital floor or a large retail box, takes an experienced estimator twenty to forty-five minutes this way. A permit set of twenty sheets is most of a day, and it lands on bid day, when the day is already full.
Where hand counts go wrong
- Strobes counted as one line when the candela tags say they are four different parts.
- Ceiling-mounted appliances counted with the wall-mounted ones, because the small C beside the symbol was missed.
- Duct smoke detectors counted as smoke detectors, or dampers counted as duct smokes.
- A typical-floor sheet multiplied by the wrong number of floors, or not multiplied at all.
- Devices on an enlarged plan or a detail counted twice, once on the plan and once on the detail.
- The second re-count after an addendum, done faster than the first, done worse.
Doing it with Fire Alarm Takeoff
Fire Alarm Takeoff is a web tool that does the sweep for you and gives you two things back: the same sheets with every device ringed and labelled, and a count grid with one row per sheet and one column per kind of device.
- Upload the set as the engineer issued it, one PDF or several, up to 100 MB. Nothing to convert.
- Point at the legend sheet, if the set has one, so the set's own symbols are read first. The legend is never charged. If there is no legend, you can type a few lines of symbol notes instead.
- Tick the plan sheets you want counted. One sheet is one page; the cost is on screen before you start.
- Download the takeoff. The marked set is a standard PDF, each ring a PDF markup with the type, candela and mounting in its label, so it opens in the PDF tool you already review in. The count grid comes as PDF, CSV and Excel, with the fire-alarm adjacent equipment in its own section, a row per floor under a typical sheet, and a total with typical floors extended.
AI-generated count. Verify before bidding. The reading is done by software, including an AI model. It can miss a device, ring something that is not one, or misread a tag. That is why every device is marked on the sheet: open the marked PDF next to the original and check what it found and what it missed. The results page lists what to look at first: types the legend does not define, strobes with no candela tag, sheets that did not finish. Sheets that do not finish are not charged.
What it costs
Pay per page, where a page is one sheet counted. Packs run from 10 pages for $24.99 ($2.50 a page) to 400 pages for $639 ($1.60 a page), before tax. Pages you buy never expire, there is no subscription, and a new account gets two pages free to try on its own sheets. The pricing page has a sheet-count estimator.
What it does not do
- It does not price anything, and it does not count wire, conduit, back boxes or labour. It gives you the device quantities your estimate starts from.
- It does not check the design against NFPA 72 or any code. Candela and spacing are read from the drawing, not judged.
- It does not multiply typical floors for you blindly. It counts the sheet once as drawn, lists each floor the sheet stands for, and shows the extended total separately, so you decide which number goes in the bid.